           Highly accurate calibration of


           RH probes and loggers




           Portable humidity generator delivers fast, accurate multi-point calibration of humidity
           probes and loggers




                omtest is offering the Fluke   Easy maintenance
                5128A RHapid-Cal Humidity    •  A front-loading desiccant cartridge can be easily changed by removing the front cap
          CGenerator, a portable, versatile    and sliding in a new one.
           humidity generator for calibrating a   •  Only clean distilled water is needed to operate the 5128A.
           large workload of probes and loggers
           in the field or laboratory. The 5128A is   The 5128A RHapid-Cal comes standard with an ISO 17025 accredited system calibration
           ideal for corporate and independent   and is backed by Fluke Calibration’s world-class metrology and support.
           calibration labs where humidity
           measurement is critical to prevent   Contact Comtest, Phone 010 595-1821, sales@comtest.co.za, www.comtest.co.za
           spoilage of products, including   Facebook: https://bit.ly/3iuk4cg
           pharmaceuticals, medical devices,   YouTube: https://bit.ly/2V4nc6j
           semiconductors, chemicals and food   LinkedIn: https://bit.ly/3rpTu86
           production.                       Product: https://bit.ly/3j58Trw
             The 5128A is lightweight and    Hashtags: #FlukeCalibration #HumidityCalibration #Comtest
           compact so technicians can easily take
           it to the field for thorough, reliable
           multi-point calibration of humidity
           probes and loggers. In the lab, the
           5128A reduces calibration time by
           at least 33 percent compared to
           traditional two-pressure humidity
           generators, which are slower to
           respond to humidity and temperature
           set point changes.

           The 5128A delivers:
           •  Best-in-class system accuracy
             of ±1,0% RH for dependable
             humidity probe calibration
           •  Rapid humidity and temperature
             stabilization time for high
             calibration throughput
           •  Rate of change for temperature
             increase is typically 10 ºC/minute;
             for temperature decrease 1,5°C/
             minute.
           •  Rate of change for humidity
             increase is typically 10% RH/
             minute; for decrease 5% RH/
             minute.
           •  A six-point calibration can be done
             in two hours.





                                                    energize | May 2022 | 10