Page 23 - EngineerIT August 2022 Digital
P. 23

INDUSTRY 4.0






















                                                               Figure 4: Block diagram of the AD74413R discrete power solution.

                                                               These capabilities allow users to remotely troubleshoot any
                                                               faults occurring in their system. In many existing systems,
                                                               sensors and actuators may be located far away from the
                                                               control room and in potentially hazardous areas. In addition,
                                                               crowded cabling may also make it difficult to determine which
                                                               cables are connected to which sensor or actuator, making it
        Figure 2: AD74413R with required external components for all functions.
                                                               cost prohibitive and time-consuming to physically rewire these
                                                               systems. The AD74413R modules provide configurability and
        Fault detection and diagnostic capabilities            diagnostics to determine which sensor or actuator is connected
        The AD74413R is equipped with automatic fault detection   to a particular channel.
        and different diagnostic functions to help in fault isolation.
        The ALERT pin is asserted and can be used to interrupt the   Isolated power and data solution
        microcontroller during a fault condition. Then users can   Discrete implementation
        interrogate an alert register to determine the exact cause of   A discrete isolated power solution for the AD74413R requires
        the fault. Users can also enable diagnostic signals to further   multiple components, as shown in Figure 4. Separate isolators
        diagnose the identified fault.                         are used to provide power and data isolation. This creates the
                                                               problem of having a large board area due to the increased
        These are the faults that can be detected by the AD74413R:  number of components.
        •  Reset
        •  Calibration memory error                            ADP1032 solution
        •  SPI CRC error                                       Figure 5 shows the block diagram of the AD74413R powered
        •  ADC error                                           by the ADP1032. The ADP1032 satisfies the requirement for
        •  Power supply error                                  isolated power and data channels by having two isolated
        •  Temperature error                                   and regulated rails and seven data isolation channels all
        •  Open-circuit/short-circuit error                    in one package. This provides a board area reduction of
                                                               ~3× compared to having discrete power and data isolation
                                                               solutions. This allows customers to increase the overall






















        Figure 3: Software configurable I/O fault detection.   Figure 5: A block diagram of the AD74413R powered by the ADP1032.


                                                  EngineerIT | August 2022 | 21