MEASUREMENT



              As with any electrical system,   the AC side, use the Fluke 393 FC to check the inverter’s output voltage and current
           check for broken wires and any      levels. Many of these systems have a display that indicates current inverter and
           loose connections. Clean all dirty   system performance. As the Fluke 393 FC produces a true-RMS reading, you can use
           connections and replace all bad     the voltage and current to measure and record the power output in kilowatt (kW).
           wiring. With the power off, check for   If possible, use the inverter display to show the current total energy in kilowatt
           and repair any ground faults. If any   hours (kWh) and compare it to the one recorded during the last inspection. When
           fuses blow or breakers trip again,   troubleshooting the DC side, use the Fluke 393 FC to check the DC power and save
           there will be a short that will need to   the reading to the Fluke Connect™ app on your phone.
           be located and repaired.                If the inverter does not produce the right amount of power, there may be a blown
              If the load still does not operate   fuse, tripped breaker or broken wires — all of which can easily be checked with the Fluke
           properly, use the Fluke 393 FC to   393 FC.
           check the system’s voltage at the
           load’s connection. The wire size   4.  Troubleshooting combiner boxes
           may be too small and need to be      When troubleshooting combiner boxes, amperage measurements and calculations are
           increased. This will show up as a low   crucial to establishing whether the PV arrays are operating correctly. Measuring current
           voltage at the load and to resolve,   on individual arrays or combining current measurements will help determine if a module
           either reduce the load on the circuit   has malfunctioned.
           or run a larger wire.                   The thinner jaw design of the Fluke 393 FC clamp meter ensures that several
                                               conductors are used in the jaw for combined current measurements, even in tight or
        3.  Troubleshooting PV inverters       crowded spaces like inverter or combiner boxes.                  n
           The inverter converts DC from
           the PV system into AC power for   Fluke is represented in South Africa by Comtest.
           building use. For troubleshooting   Visit www.comtest.co.za or call 010 595 1821