Page 12 - Issue 1 2023
P. 12

DATA AND SOFTWARE



        after the incident, poisoning the work
        environment and, if left unchecked,
        can lead to poor delivery at best and
        multiple resignations at worst.
           It was this challenge of early
        detection and intervention that gave
        us the idea of turning our software
        development skills to building a system
        that could help us minimise the fallout
        of team discord.
           By applying an algorithm to our
        data, the software can give insight
        into the relationships between team
        members and how that could impact
        current projects. We have found that   resignation, not to mention the lack of continuity and lost IP, it’s easy to see that early
        the software is able to detect points of   intervention was having a material impact on operations.
        potential conflict between six weeks to   While we are nowhere near a world where machines could or should replace
        two months before a human would.     humans when it comes to complex human capital management, by analysing
           We saw that early intervention    responses our TeamFirst software is able to detect around 80 percent of potential
        slashed staff turnover by 50 percent   team issues, pre-empting conflict before it reaches senior management. This doesn’t
        in the first year. Considering replacing   just preserve management focus, but it puts project managers and team leads back in
        a developer was costing upwards      control of their departments and helps create a work environment that is primed for
        of R100 000 each time there was a    profitability.








              THE ISOFACE™ OUTPUT SWITCHES


         AND THE ISOFACE™ DIGITAL INPUT ICS

        ISOFACE™ digital in- and output switches and ICs are intelligent system solutions offering robust
          galvanic isolation between the µC on the control side and the 24V factory floor environment.

                                                    3.3V µC Domain
                                                       Control Side



                                                     DI  DO   AI  AO   µC PSU
             ISOF
                  CE™
                 A
             ISOFACE™                                                                            ISOFACE™
             Input ICs                                                                        Output Switches
        Infineon’s galvanically                    24V Factory Floor                          Galvanically isolated
        Isolated 8-channel                             Process Side                           8-channel ISOFACE™
        digital input IC                     Valve                            Sensor              output switches
                                             Control
        switches are ideal                                                                         can be used to
                                             Load                             Sensor
        for highly compact                   Control                                              drive any kind of
        industrial applications.             Motor                            Sensor          resistive, inductive, or
                                             Control                          Module
                                                                                                 capacitive loads.
                                             Motor                            Sensor
                                             Control                          Module
                              Motor          Motor
                              Control        Control
                                                                   Power-Bus
                                                            Robot
                                                           Control
                                              For more information please contact Willem Schmidt
                                              on 084 209 5458 or wschmidt@arrow.altech.co.za