Figure 11: Power saving options and power monitor mode configuration in TES.

        boards are supported by TES.  All the power saving options including monitor mode could be   Analog Devices is represented in South
                             3
        configured in TES, as shown in Figure 11.                                 Africa by Altron Arrow. For more
           The self-explanatory power saving configuration pages are very easy to use. To help   information contact Conrad Coetzee at
        users further evaluate power consumption, the ADRV9001 EVB is equipped with a power   ccoetzee@arrow.altec.co.za
        monitor chip to monitor and measure the power consumption in real time. Detailed power
        consumption at different power domains can be displayed in TES at 30 second intervals,   About the Author
        as shown in figure 12, which is a powerful visual tool to evaluate the power performance   Mizhou (Michelle) Tan is a product
        on-the-fly at different channel states. Good measurement accuracy can be achieved within   applications engineer with Analog
        ±2.5% error tolerance.                                                     Devices. She has supported the design and
                                                                                   development of RF transceiver products
        Conclusion                                                                 and applications for about 3 years. Prior to
        As discussed in this article, empowered with a variety of power saving options at the   joining ADI, she received her B.S. degree
        component, channel, and system levels, as well as the monitor mode, the ADRV9001   and M.S degree in electrical engineering
        transceiver family is able to achieve a scalable power and performance for many mission   from Sichuan University in China and her
        critical applications. Understanding the associated performance trade-offs for each power   Ph.D. degree in electrical and computer
        saving option is crucial to determine the best system power saving strategy. All power saving   engineering from New Jersey Institute
        options can be thoroughly evaluated through the ADRV9001 TES and EVB by a powerful real-  of Technology in 2004. After that, she
                                                                                   worked as an algorithm, system, and
        time display of power consumptions on all power domains with a high accuracy.   n
                                                                                   software engineer at Agere Systems, LSI
                                                                                   Logic, and Intel® Corp. from 2004 to 2018.
        References                                                                 She has published more than 15 papers
        1. “Two-Way Radios and Battery Life.” Hytera Europe, December 2016.        in technical conferences and journals
        2. ADRV9002 Dual Narrow-Band and Wideband RF Transceiver Data Sheet. Analog Devices,   and owns nine issued patents in the
          Inc., April 2021.                                                        wireless communication and digital signal
        3. ADRV9001 System Development User Guide. Analog Devices, Inc., October 2021.  processing area. She can be reached at
                                                                                   mizhou.tan@analog.com.





















        Figure 12: Power consumption real-time display using TES.



                                                    EngineerIT | April 2022 | 20